EPA Certified

At County Fair Air Conditioning, we believe that a key component to our contribution to a better environment is the proper handling of fluorocarbon refrigerants. By our efforts to recover, recycle and reclaim used refrigerants, large quantities of ozone depleting gases can be reprocessed for further commercial use or safely destroyed.

There are many environmental and economic benefits to be gained by providing this service to our customers. Some of the major benefits include:

  • Reduced environmental compliance costs
  • Reduced need for new refrigerant
  • Increased lifetime of air conditioning equipment due to contaminant removal
  • Minimized atmospheric emissions and a reduced environmental impact

It is also our policy to provide high efficiency options when proposing replacement equipment and components. Our technicians are trained and informed as to the latest advances in our industry.

Our recommendations are not limited to HVAC related issues. If we see cost or energy savings possible from other improvements that our customers can make, we will bring them to their attention.

The following information was taken from the United States Environmental Protection Agency’s website and provides information on the phase-out of refrigerant R-22.

Ban on Production and Imports of Ozone-Depleting Refrigerants

In 1987 the Montreal Protocol, international environmental agreement, established requirements that began the worldwide phase-out of ozone-depleting CFCs (chlorofluorocarbons). These requirements were later modified, leading to the phase-out in 1996 of CFC production in all developed nations. In 1992 the Montreal Protocol was amended to establish a schedule for the phase-out of HCFCs (hydrochlorofluorocarbons). HCFCs are less damaging to the ozone layer than CFCs, but still contain ozone-destroying chlorine. The Montreal Protocol as amended is carried out in the U.S. through Title VI of the Clean Air Act, which is implemented by EPA.

HCFC-22 (also known as R-22) has been the refrigerant of choice for air-conditioning systems for more than four decades. Unfortunately for the environment, releases of R-22, such as those from leaks, contribute to ozone depletion. In addition, R-22 is a greenhouse gas and the manufacture of R-22 results in a by-product (HFC-23) that contributes significantly to global warming. As the manufacture of R-22 is phased out over the coming years as part of the agreement to end production of HCFCs, manufacturers of air conditioning systems are offering equipment that uses ozone-friendly refrigerants. Many building owners may be misinformed about how much longer R-22 will be available to service their air conditioning systems and heat pumps. The following information provides information about the transition away from R-22, the future availability of R-22, and the new refrigerants that are replacing R-22. This document also assists consumers in deciding what to consider when purchasing a new air conditioning system or heat pump, or when having an existing system repaired.

Phase-out Schedule for HCFCs Including R-22

Under the terms of the Montreal Protocol, the U.S. agreed to meet certain obligations by specific dates that will affect the air conditioning industry:

January 1, 2004:
The Montreal Protocol required the U.S. to reduce its consumption of HCFCs by 35% below the U.S. baseline cap. As of January 1, 2003, EPA banned production and import of HCFC-141b, the most ozone-destructive HCFC. This action allowed the United States to meet its obligations under the Montreal rotocol. EPA was able to issue 100% of company baseline allowances for production and import of HCFC-22 and HCFC-142b.
January 1, 2010:
The Montreal Protocol requires the U.S. to reduce its consumption of HCFCs by 75% below the U.S. baseline. Allowance holders may only produce or import HCFC-22 to service existing equipment. Virgin R-22 may not be used in new equipment. As a result, heating, ventilation and air-conditioning (HVAC) system manufacturers may not produce new air conditioners and heat pumps containing R-22.
January 1, 2015:
The Montreal Protocol requires the U.S. to reduce its consumption of HCFCs by 90% below the U.S. baseline.
January 1, 2020:
The Montreal Protocol requires the U.S. to reduce its consumption of HCFCs by 99.5% below the U.S. baseline. Refrigerant that has been recovered and recycled/reclaimed will be allowed beyond 2020 to service existing systems, but chemical manufacturers will no longer be able to produce R-22 to service existing air conditioners and heat pumps.

What Does the HCFC-22 Phase-out Mean for Consumers?

Availability of R-22

The Clean Air Act does not allow any refrigerant to be vented into the atmosphere during installation, service, or retirement of equipment. Therefore, R-22 must be recovered and recycled (for reuse in the same system), reclaimed (reprocessed to the same purity standard as new R-22), or destroyed. After 2020, the servicing of R-22-based systems will rely solely on recycled or reclaimed refrigerants. It is expected that reclamation and recycling will ensure that existing supplies of R-22 will last longer and be available to service a greater number of systems. As noted above, chemical manufacturers will no longer be able to produce, and companies will no longer be able to import, R-22 for use in new air conditioning equipment after 2010, but they can continue production and import of R-22 until 2020 for use in servicing existing equipment. Given this schedule, which was established in 1993, the transition away from R-22 to the use of ozone-friendly refrigerants should be smooth. For the next 10 years or more, R-22 should continue to be available for all systems that require R-22 for servicing.

Alternatives to R-22 in Residential Air Conditioning

As R-22 is gradually phased out, non-ozone-depleting alternative refrigerants are being introduced. Under the Clean Air Act, EPA reviews alternatives to ozone-depleting substances to evaluate their effects on human health and the environment. EPA has reviewed several alternatives to R-22 for household and light commercial air conditioning and has compiled a list of substitutes that EPA has determined are acceptable. One of these substitutes is R-410A, a blend of hydrofluorocarbons (HFCs) that does not contribute to depletion of the ozone layer, but, like R-22, contributes to global warming. R-410A is manufactured and sold under various trade names, including GENETRON AZ-20®, SUVA 410A®, Forane® 410A, and Puron®. An additional refrigerant on the list of acceptable substitutes for R-22 in residential air conditioners and other products is R-407C. Residential air conditioners and heat pumps using R-407C are not available in the U.S., but are commonly found in Europe. EPA will continue to review new non-ozone-depleting refrigerants as they are developed.

Servicing existing units

Existing units using R-22 can continue to be serviced with R-22. There is no EPA requirement to change or convert R-22 units for use with a non-ozone-depleting substitute refrigerant. Such changes, called “retrofits,” are allowed if the alternative has been found acceptable for that type of use.  R-407C is allowed for retrofits but R-410A is not allowed in retrofits due to its higher working pressures. In addition, the new substitute refrigerants would not work well without making some changes to system components. As a result, service technicians who repair leaks to the system will most often continue to charge R-22 into the system as part of that repair.

Installing new units

The transition away from ozone-depleting R-22 to systems that rely on replacement refrigerants like R-410A has required redesign of heat pump and air conditioning systems. New systems incorporate compressors and other components specifically designed for use with specific replacement refrigerants. For instance, if a new outdoor unit (typically called a “condensing unit,” containing the condenser and compressor) is installed, it is likely that a new indoor unit (typically called an “evaporator”) will also be required. With these significant product and production process changes, testing and training must also change. Consumers should be aware that dealers of systems that use substitute refrigerants should be schooled in installation and service techniques required for use of that substitute refrigerant.

A Common Sense Approach to Servicing Your System

Along with prohibiting the production of ozone-depleting refrigerants, the Clean Air Act also mandates the use of common sense in handling refrigerants. By containing and using refrigerants responsibly — that is, by recovering, recycling, and reclaiming, and by reducing leaks — their ozone depletion and global warming consequences are reduced. The Clean Air Act outlines specific refrigerant containment and management practices for HVAC manufacturers, distributors, dealers and technicians. Properly installed home comfort systems rarely develop major refrigerant leaks, and with proper servicing, a system using R-22, R-410A, or another refrigerant will reduce its impact on the environment. While EPA does not mandate repairing or replacing small systems because of leaks, system leaks can not only harm the environment, but also result in increased operation and maintenance costs.

One important thing a property owner or manager can do for the environment, regardless of the refrigerant used, is to select a reputable dealer that employs service technicians who are EPA-certified to handle refrigerants. Technicians often call this certification “Section 608 certification,” referring to the part of the Clean Air Act that requires minimizing releases of ozone-depleting chemicals from HVAC equipment.